- Oil mist cloud ignites
- pressure rises in the machine
- Pressure wave travels out from ignition location


- First flames appear in the machine
- Pressure wave reaches LTA pressure relief flap and opens it
- Flame front follows the pressure wave
- Fire protection flap is closed, no more extraction of oil mist, extraction unit protection from damage
- Pressure relief flap is closed
- No more oxygen supply